Automatically combines batteries during charging, isolates batteries when discharging and when starting engines
Features
Optional Features
| Nominal Voltage | 12V DC |
| 24V DC | |
| Start Isolation | Yes |
| Amperage Operating Current | 175mA (combined) |
| 15mA (open) | |
| Terminal Stud Torque | 140 in-lb (15.82 Nm) |
| Continuous Rating | 120A |
| Intermittent Rating | 210A (5 min) |
| Cable Size to Meet Ratings | 1/0 AWG |
| Terminal Ring Diameter Clearance | 1.12in (28.45 mm) |
| Terminal Stud Length | 0.875in (22.23 mm) |
| Terminal Stud Size | 3/8" – 16 (M10) |
| Relay Contact Position | |
| Combine 30 sec | 13.6V @ 12 V |
| 27.2V @ 24 V | |
| Combine 90 sec | 13.0V @ 12 V |
| 26.0V @ 24 V | |
| Open 10 sec | 12.35V @ 12 V |
| 24.7V @ 24 V | |
| Open 30 sec | 12.75V @ 12 V |
| 25.5V @ 24 V | |
| Open High | 16.0V @ 12 V |
| 30.0V @ 24 V | |
| Over Voltage Lockout | 16.0V @ 12V |
| 32.0V @ 24V | |
| Under Voltage Lockout | 9.5V @ 12 V |
| 19V @ 24 V | |
| Weight | 1.25lb (0.57 kg) |
| Code | 7610 |